Membrane method gas separation membrane-Waste gas treatment and recovery
(一)The two main methods
1.By using velocity difference of different gas through the membrane,through the fast part gathered at the sides of the membrane, through the slow part gathered at the side of inlet.
2.Using gas react with some kind of absorption solution for recycling process,when the waste gas enter into the gas separation membrane,the gas to be treated through the membrane wall hole to react with some absorption liquid on the other side of the membrane to achieve the purpose of recycling.

Structure diagram


(二)Design parameters

Name

Model

Rated volume(KG/D

Design volume(KG/D

Operation mode

Size inch

Effective length

Diameter

Gas separation membrane

KJ-NH-M4.5S

50

12~25

Blower blowing

20

4.5

KJ-NH-M4.8

120

30~60

40

4.8

KJ-NH-M7

300

75~150

40

7.0


2800KG/D-(LED) Ammonia recovery project with ammonia containing waste gas treatment

Blower section

Exhaust gas filtering and cooling section

Gas separation membrane